Tankless Flow Calculator

A tankless heater makes hot water as you use it, so its size comes down to flow and temperature rise. Choose the showers and fixtures that run at the same time to see what a unit has to deliver.

Pick your place and we set the incoming water temperature from its winter weather.

Showers running at once
At the same time as the showers

What runs at the same time

A tank stores hot water. A tankless unit makes it as you go, so it is sized in gallons per minute, not gallons. Add up what realistically runs together. We use 2.5 gallons per minute for a showerhead, which is the federal limit, about 1.8 for a faucet and about 2 for a dishwasher or washer. Two showers at once already means 5.

How cold the water comes in

The unit has to lift incoming water up to the setpoint, and the tool uses 120°F. With a January average low of 25°F, it figures Paterson’s incoming water at 52°F, a rise of 68°F. Colder places are figured at 42°F and milder ones at 65°F.

How the size is worked out

The heat a unit has to deliver each hour is the flow in gallons per minute, times the rise in degrees, times 500. That figure comes from the weight of a gallon of water. We round it and place it in one of our own planning bands, based on that delivered heat. Up to 90,000 BTU per hour is a small unit. Up to 150,000 is a standard whole-house unit. Up to 190,000 is a large unit. Above that, two units are linked together.

A tankless unit trades flow for rise. The same unit gives more gallons per minute at a small rise than at a big one, which is why every tankless rating is stated at a rise.

Gas and electric limits

Gas units go up to about 199,000 BTU per hour of input, and two can be linked. Electric units top out near 36 kW, about 123,000 BTU per hour, and they need a very large electrical service. The result shows how many gallons per minute each one delivers at your rise. A plumber or an electrician checks the gas line, the electrical service and the venting before any unit is chosen.

Common questions

What size tankless water heater do I need for a family of four?

Plan on the flow for two showers at once, about 5 gallons per minute. At Paterson’s 68°F rise that is about 170,000 BTU per hour, which puts it in the large unit class. The calculator shows the class for your own mix of showers and fixtures.

Can a tankless water heater run two showers at once?

Yes, with the right unit. Two showers is about 5 gallons per minute, and one large gas unit covers about 5.6 gallons per minute at a 68°F rise. Adding a faucet or an appliance can push the load to two linked units.

What is temperature rise on a tankless water heater?

It is the gap between the incoming water temperature and the setpoint. With 120°F out and 52°F in, the rise is 68°F. Every tankless flow rating is stated at a rise, so a unit delivers fewer gallons per minute when the water comes in colder.

Is an electric tankless water heater enough for a whole house?

Not for two showers. The largest electric units, about 36 kW, deliver around 3.6 gallons per minute at a 68°F rise, which is under the 5 gallons two showers need. They also need a very large electrical service that an electrician has to confirm.

Does a tankless water heater need a bigger gas line?

Often. A 199,000 BTU per hour unit draws several times what a tank heater does, and the existing gas line and venting may not be sized for it. A plumber checks both first.

Data: fixture flow rates from the federal showerhead limit and typical faucet and appliance flows, the 120°F setpoint recommended by the US Department of Energy, and incoming water bands set from Daymet winter data 2015 to 2024 for each place.